Author: ITC India

Recalibrate pyranometer every 2 years……….

Recalibrate pyranometer every 2 years………. It is advised to recalibrate Pyranometer after every two years as the sensitivity of pyranometer slightly changes. The recalibration provides the proof of correct irradiance measurements. It also increases the confidence on the stability of the equipment. On re calibrating pyranometer and recieving new sensitivity certificate , one gets sure of…

Thermopile Pyranometer calibration by ITC India Pvt Ltd

Thermopile Pyranometer calibration by ITC India Pvt Ltd ITC India has diversify in Thermopile pyranometer calibration as per ISO 9847 standards . So, lets connect with us to calibrate your pyranometer. Before the calibration of pyranometer let us discuss about Why Thermopile pyranometer ? Here is the table that makes the clear difference why thermipile…

How can you avoid EMC Failure?

Avoid EMC Failure When Product reaches the final stage of EMC testing and fails, this is a too frightening situation. To avoid such situation, compliance testing should be introduced in the projects from day one. Examining emissions from the product during each major development stages is the ultimate method to elude costly retesting and high…

ISO 9847 Calibration of Field Pyranometers

ISO 9847 Calibration of Field Pyranometers by Comparison to a Reference Pyranometer. Are you looking for your pyranometer to be calibrated, ITC India Pvt Ltd has the facility to calibrate thermopile pyranometer at Lab and onsight. You are most welcome in ITC India Pvt Ltd for Pyranometer calibration. Either you can send the Pyranometer in the Lab or onsight…

BS EN 1838:2013 Emergency Lightning BS EN 1838:2013 Emergency Lightning

BS EN 1838:2013 Emergency Lighting

BS EN 1838:2013 Emergency Lighting Testing First of all, What is BS EN 1838:2013 standard? This standard states general rules for emergency escape lighting and standby lighting systems installed in an office, property, site, building or working place where such systems are required. These areas are predominantly where the public or workers have access.  …

IEC 60896-22 Stationary lead-acid batteries – Part 22

IEC 60896-22 Stationary lead-acid batteries – Part 22 Valve regulated types – Requirements ITC India Pvt Ltd is India’s leading inspection, verification, testing and certification company.ITC is known world wide benchmark for quality and integrity. We believe in providing our customers best services and better guidance. ITC have an ability to turn client needs into…

Stationary Lead Acid Battery

Stationary Lead Acid Battery

Stationary Lead Acid Battery IEC 60896-22 is applicable to  :- All stationary Lead-acid cells Monobloc batteries of the valve regulated type For Float charge application: They can be permanently connected to a load and d.c. power supply. In a static location: not generally moved from place to place. They are incorporated into stationary equipment or…

Cable tray Safe Working Load Test (SWL)

Cable tray Safe Working Load Test (SWL) Cable tray/ Protective castings must be designed to the below said ambient temperatures -25 ºC to 90 ºC for outdoor use +5 ºC to 90 ºC for indoor use. Safe working load is one of the mechanical requirements assigned to meet by the cable tray/ protective castings. Another…