What Is IP?

IP is knownas Ingress Protection,Classifies and Rates the degree of protection provided against Enclosure,dust, accidental contact, and water by mechanical casings and electrical enclosures. For more info Visit our Website www.itcindia.comor mail us on info@itcindia.org

Our Accreditations (ITC India Pvt.Ltd.)

ITC India Electrical Safety Testing Laboratory Accreditated by NABL (ISO/IEC 17025) & BIS. For any query Email us (info@itcindia.org) or Visit our Website (www.itcindia.org)

IEC

To Classifies and Rates the degree of protectionIEC (International Electro-technical Commission) Introducesa standard IEC 60529.

What is IEC 60529:

IEC 60259standard determines how well a enclosure(EUT)protects internal working parts from dust& water and fingers, tools, and wires. It is used for consumer safety and enclosure testing.

Scope of This Standard :

This standard applies to the classification of degrees of protection provided by enclosures for electrical equipment with a rated voltage not exceeding 72,5 kV

IEC 60259 : Dust and Water Resistance by Category

The IEC 60259ratings use a two-digit system to Providethe level of protection that each product features. Ratings are listed as “IP__ __,” with the first digit indicating solid ingress protection, and the second digit representing liquid ingress protection. Additional letters may follow the two digits, specifying additional ingress protection.

There are six levels of solid ingress protection under the IEC 60259 rating system:
lThe product is protected against entryby a solid object larger than 50 mm in size, such as a hand.
lThe product is protected against entryfrom solid objects larger than 12.5 mm, such as a finger
lThe product is protected against entryof solid objects larger than 2.5 mm, such as a screwdriver
lThe product protects against entryby solid objects larger than 1mm, such as a wire
lThe product is protected against a limited amount of dust exposure. Dust entrywill not interfere/Degradewith product operation assuming dust exposure
lTotal dust protection. Dust ingress is not possible to enter in Product during Testing

ITC India Pvt. Ltd.Electrical Safety Testing Laboratory Accreditated by NABL (ISO/IEC 17025) & BIS. For any query Email us (info@itcindia.org) or Visit our Website (www.itcindia.org)

Equipments Used for IP Testing (Solid)

Equipments Used For IP Testing Solid

Second digit representing nine levels of water ingress protection
lThe product is protected under vertically falling water drops. Some limited ingress is allowed
lWhen tilted at 15° from the vertical, the product resists vertically falling water drops. Again, limited ingress is permitted
lWhen water sprays are applied up to 60° from the vertical, the product allows limited intrusion for a period of three minutes
lThe product allows limited ingress when water is splashed on it from all directions
lLimited ingress is permitted when water jets are applied to the product
lHeavy seawater and powerful jets of water will not enter the product in damaging quantities
lThe product is protected against the effects of water intrusion when immersed in water between 15 cm and 1 m for up to 30 minutes
lThe product withstands water intrusion when immersed in water under pressure for long periods
lThe product is protected against the effects of high-pressure and high-temperature water jets

Equipments Used for IP Testing(Water)

Equipments Used For IP TestingWater