Safety Testing As Per IEC 60335-1

Scope of IEC 60335-1

This International Standard deals with the safety of electric room heaters for household and similar purposes, their rated voltage being not more than 250 V for single-phase appliances and 480 V for other appliances.

IEC 60335-2-24

Refrigerators, Freezers, Ice makers etc. are used nearly at every place globally. Refrigerators, Freezers & ice making products face a changing landscape with increased demands for energy efficiency and transition to low global warming potential refrigerants. We ITC India provide the safety testing as per standard IEC 60335-2-24, as well as energy efficiency.

What is IEC 60335-2-24?

This International Standard deals with the safety of the refrigerating appliances for household and similar use, ice-makers incorporating a motor-compressor and ice-makers intended to be incorporated in frozen food storage compartments, refrigerating appliances and ice-makers for use in camping, touring caravans and boats for leisure purposes, their rated voltage being not more than 250 V for single-phase appliances, 480 V for other appliances and 24 V d.c. for appliances when battery operated.

IEC 60335-2-30 & IS 302-2-30

Room heaters are perfect home appliances to keep you comfortable during cold winter. At Cold areas especially northern India wearing warm clothes is just not enough because you need to have room heaters installed at your place to bear with the cold winter days, particularly mornings and evenings. If you are looking for Room Heater testing, ITC India provides Room heater safety testing as per standards IEC 60335-2-30 & IS 302-2-30.

Our Accreditation (ITC India Pvt. Ltd)

ITC India Electrical Safety testing laboratory Accredited by (ISO/IEC 17025) & BIS.

Or any Query Email us info@itcindia.org or visit our website www.itcindia.org.

List of Test as per IEC 60335-2-24:-

S.No.Clause No.Title of test
1.7Marking and instructions
2.8Protection against access to live parts
3.10Power input and current
4.11Heating
5.13Leakage current and electric strength at operating temperature
6.14Transient overvoltages
7.15Moisture resistance
8.16Leakage current and electric strength
9.18Endurance
10.19Abnormal operation
11.20Stability and mechanical hazards
12.21Mechanical strength
13.22Construction
14.23Internal wiring
15.24Components
16.25Supply connection and external flexible cords
17.26Terminals for external conductors
18.27Provision for earthing
19.28Screws and connections
20.29Clearances, creepage distances and solid insulation
21.30Resistance to heat and fire
22.31Resistance to rusting