Efficiency test method IEC 60034-2-1 / IS 15999 (Part 2/Sec 1)
Applicable to:
Rotating Electric Machine: IEC 60034 is introducing to establish methods of determining efficiencies from tests and also to specify methods of obtaining specific losses.
- C. Machine
- C. Synchronous
- Induction Machine (All Size in scope IEC 60034)
- Rotary Converters
- AC Commutator Motors
- Single Phase Induction Motor
Why high efficient Motors?
- Save energy
- Reduce operation cost
- Reduce harmful greenhouse gases
Order of tests IEC 60034-2-1
Step No. | Description |
1 | First stator winding resistance measurement at ambient temperature |
2 | Remove accessible drive end sealing elements (without dismantling the motor) |
3 | Clause 6.4.4.1 Rated load temperature test |
4 | Second stator winding resistance measurement (immediately after 6.4.4.1) |
5 | Clause 6.4.4.2 and 6.4.5.3 Load curve test with torque measurement (immediately after 6.4.4.1) |
6 | Third stator winding resistance measurement (immediately after 6.4.4.2 and 6.4.5.3) |
7 | Clause 6.4.2 No load test (immediately after third stator winding resistance measurement) |
8 | Fourth stator winding resistance measurement (immediately after 6.4.2) |
Determination of loss components must be performed in the following order |
|
9 | Clause 8.2.2.3 Constant losses (8.2.2.3.1, 8.2.2.3.2 and 8.2.2.3.3)
Constant losses to Clause 8.2.2.3.1 (Friction and windage losses: 8.2.2.3.2) (Iron losses: 8.2.2.3.3) |
10 | Clause 8.2.2.4 Load losses (8.2.2.4.1.2 and 8.2.2.4.1.3)
Load losses to Clause 8.2.2.4.1: (Stator and rotor winding losses s, including temp. correction) (8.2.2.4.1.2 and 8.2.2.4.1.3) |
11 | Clause 8.2.2.5 Additional load losses (8.2.2.5.1 From a load test with torque measurement)
Additional load losses to Clause 8.2.2.5.1 (Residual losses) |
12 | Clause 8.2.2.2 Calculate total losses |
13 | Clause 8.2.2.1 Calculate the efficiency |